This module exploits a series of vulnerabilities to achieve unauthenticated remote code execution on the Rockwell FactoryTalk View SE SCADA product as the IIS user. The attack relies on the chaining of five separate vulnerabilities. The first vulnerability is an unauthenticated project copy request, the second is a directory traversal, and the third is a race condition. In order to achieve full remote code execution on all targets, two information leak vulnerabilities are also abused. This exploit was used by the Flashback team (Pedro Ribeiro + Radek Domanski) in Pwn2Own Miami 2020 to win the EWS category.
Exploit database
Vulnerability
CVE-2020-12027
Rockwell Automation FactoryTalk View SE
Vulnerability details
- Score
- 4.3
- Severity
- medium
CVSS 3.1 · icscert
Vector string
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:NDescription
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
CVE ProgramShowing saved CVE details. Refresh is temporarily unavailable.
Exploit source choices
1 sourceRockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution
2020-06-22rockwell_factorytalk_rce.rb