Vulnerability
CVE-2018-9276
Vulnerability details
- Score
- 7.2
- Severity
- high
CVSS 3.1 · CISA-ADP
Vector string
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HDescription
An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.
CVE ProgramExploit source choices
3 sourcesNotifications can be created by an authenticated user and can execute scripts when triggered. Due to a poorly validated input on the script name, it is possible to chain it with a user-supplied command allowing command execution under the context of privileged user. The module uses provided credentials to log in to the web interface, then creates and triggers a malicious notification to perform RCE using a Powershell payload. It may require a few tries to get a shell because notifications are queued up on the server. This vulnerability affects versions prior to 18.2.39. See references for more details about the vulnerability allowing RCE.
CVE-2018-9276 PRTG < 18.2.39 Authenticated Command Injection (Reverse Shell)