Vulnerability
CVE-2011-1563
Vulnerability details
- Score
- Not available
- Severity
- Not available
Vector string
Not availableDescription
Multiple stack-based buffer overflows in the HMI application in DATAC RealFlex RealWin 2.1 (Build 6.1.10.10) and earlier allow remote attackers to execute arbitrary code via (1) a long username in an On_FC_CONNECT_FCS_LOGIN packet, and crafted (2) On_FC_CTAGLIST_FCS_CADDTAG, (3) On_FC_CTAGLIST_FCS_CDELTAG, (4) On_FC_CTAGLIST_FCS_ADDTAGMS, (5) On_FC_RFUSER_FCS_LOGIN, (6) unspecified "On_FC_BINFILE_FCS_*FILE", (7) On_FC_CGETTAG_FCS_GETTELEMETRY, (8) On_FC_CGETTAG_FCS_GETCHANNELTELEMETRY, (9) On_FC_CGETTAG_FCS_SETTELEMETRY, (10) On_FC_CGETTAG_FCS_SETCHANNELTELEMETRY, and (11) On_FC_SCRIPT_FCS_STARTPROG packets to port 910.
CVE ProgramSome CVE details could not be loaded. They will be retried.
Exploit source choices
3 sourcesThis module exploits a vulnerability found in DATAC Control International RealWin SCADA Server 2.1 and below. By supplying a specially crafted On_FC_BINFILE_FCS_*FILE packet via port 910, RealWin will try to create a file (which would be saved to C:\Program Files\DATAC\Real Win\RW-version\filename) by first copying the user- supplied filename with an inline memcpy routine without proper bounds checking, which results a stack-based buffer overflow, allowing arbitrary remote code execution. Tested version: 2.0 (Build 6.1.8.10)
This module exploits a stack buffer overflow in DATAC Control International RealWin SCADA Server 2.1 (Build 6.0.10.10) or earlier. By sending a specially crafted On_FC_CONNECT_FCS_LOGIN packet containing a long username, an attacker may be able to execute arbitrary code.